FDA PMA supplement record

P960040/S516

ICD INOGEN™ VR DF4 (D010); ICD INOGEN™ VR DF1/IS1 (D011); ICD INOGEN™ DR DF4/IS1 (D012); ICD INOGEN™ DR DF1/IS1 (D013); (truncated in the FDA record)

Supplement S516 to premarket approval P960040. Product code LWS. Decision 23 July 2026.

Approval

Each row is one field of the openFDA record. The grey name is the field’s name in openFDA’s documentation.

FieldValueField name
PMA numberP960040pma_number
Supplement numberS516supplement_number
ApplicantBoston Scientificapplicant
Trade nameICD INOGEN™ VR DF4 (D010); ICD INOGEN™ VR DF1/IS1 (D011); ICD INOGEN™ DR DF4/IS1 (D012); ICD INOGEN™ DR DF1/IS1 (D013); (truncated in the FDA record)trade_name
Generic nameImplantable cardioverter defibrillator (non-CRT)generic_name
Product codeLWSproduct_code
Advisory committeeCardiovascularadvisory_committee_description
Date received2026-06-26date_received
Decision date2026-07-23decision_date
Decision codeOK30decision_code
Supplement type30-Day Noticesupplement_type
Supplement reasonProcess Change - Manufacturer/Sterilizer/Packager/Suppliersupplement_reason

Source: FDA openFDA, device/pma, P960040/S516, retrieved 2026-09-19 21:55 Eastern. Public domain (CC0).

Product code

The FDA classification record for the code on this record.

LWS

Implantable Cardioverter Defibrillator (Non-Crt)

Device class 3 · Review panel CV

ArrHub vocabulary

Electrophysiology

LWS is one of the 56 product codes in ArrHub’s electrophysiology vocabulary, each held with its FDA classification record as its citation. Vocabulary entry verified 20 September 2026.

Supplement history

Every record of this PMA number in ArrHub’s verified view, newest first. Routine notices are listed, never summarised away.

RecordTypeReasonDecision
P960040 FDAoriginal approvalempty1997-07-18
P960040/S515 FDAReal-Time ProcessChange Design/Components/Specifications/Material2026-08-25
P960040/S516 FDA30-Day NoticeProcess Change - Manufacturer/Sterilizer/Packager/Supplier2026-07-23
P960040/S513 FDAReal-Time ProcessChange Design/Components/Specifications/Material2026-07-01
P960040/S514 FDA30-Day NoticeProcess Change - Manufacturer/Sterilizer/Packager/Supplier2026-06-03
P960040/S507 FDANormal 180 Day TrackChange Design/Components/Specifications/Material2026-04-21
P960040/S512 FDA30-Day NoticeProcess Change - Manufacturer/Sterilizer/Packager/Supplier2026-04-01
P960040/S505 FDA135 Review Track For 30-Day NoticeProcess Change - Manufacturer/Sterilizer/Packager/Supplier2026-01-08

Source: FDA openFDA, device/pma, records of P960040, retrieved 2026-09-19 21:55 Eastern. 8 records in the verified view. Each identifier links to the FDA’s page.

ArrHub

What ArrHub adds to the record. Everything above this line is the agency’s; everything here is ArrHub’s, dated and attributed.

Record pair

No confirmed pair across the two registers for this record.

Resolved to

Boston Scientific

The register name above is resolved to its organisation under ArrHub’s alias table. Method: rule:normalize. Source: fda_applicant. Verified 20 September 2026.

First seen by ArrHub’s weekly snapshot: 2026-09-20 08:40 Eastern.

Raw record

The stored record exactly as ArrHub holds it, for anyone who wants to check the page against it.

Show the raw record (JSON)device/pma.json?search=pma_number:P960040+AND+supplement_number:S516&limit=1
{
  "id": "52409497-8041-42c7-a568-6b3d8233ae6c",
  "pma_key": "P960040/S516",
  "pma_number": "P960040",
  "supplement_number": "S516",
  "applicant": "Boston Scientific",
  "trade_name": "ICD INOGEN™ VR DF4 (D010); ICD INOGEN™ VR DF1/IS1 (D011); ICD INOGEN™ DR DF4/IS1 (D012); ICD INOGEN™ DR DF1/IS1 (D013);",
  "generic_name": "Implantable cardioverter defibrillator (non-CRT)",
  "product_code": "LWS",
  "advisory_committee_description": "Cardiovascular",
  "decision_date": "2026-07-23",
  "decision_code": "OK30",
  "supplement_type": "30-Day Notice",
  "supplement_reason": "Process Change - Manufacturer/Sterilizer/Packager/Supplier",
  "date_received": "2026-06-26",
  "source_url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960040&s=S516",
  "verified_at": "2026-09-20T02:05:49.025+00:00",
  "created_at": "2026-09-20T01:55:45.395466+00:00",
  "collected_at": "2026-09-20T01:55:31.069+00:00",
  "last_checked_at": null
}

The readable page is rendered from the record held in ArrHub’s verified view; the agency record at api.fda.gov governs where they differ.

Links open the agency’s own records. Unlabelled links open web pages. Links marked (JSON) open an agency’s data record, which a browser shows as plain text.

Report a broken link or a record that does not match its source: alerts@arrhub.com. Corrections are published, with their date, at arrhub.com/corrections.

© 2026 ArrHub. Content made available under licence.